Cycle Analyst 4.0a50 - Release Notes
SETTINGS SUMMARY    CAV4 ONLINE

----- Summary of Changes in this Release -----


Section titles show the feature/problem tracking number and description.


Release: 4.0a50                                                      2020-05-16

    This version is pre-release development firmware packaged exclusively for
    in-house test.  Improper operation may occur.

    IMPORTANT NOTES - Please Read Carefully!

    NOTE: This firmware is instrumented to detect illegal writes to any setting
          in EEPROM.  The CA intercepts these errors before they occur, ceases
          normal operation, and displays a special 'Watch EE' screen.  A similar
          'StkTrace' screen will also appear if other non-recoverable internal
          errors occur.
          
          If one of these screens appear, please record all screen information
          either by manual transcription or multiple phone photos, press the
          right console button, and repeat until all screens have been recorded
          and the CA reboots.

          Please forward the recorded information with a description of the
          failure circumstances to Grin at: info@ebikes.ca.  Please include a
          setup file if possible. Thank you!

    NOTE: This firmware in instrumented to detect incomplete save of Trip Data
          to EEPROM on power down. If this process does not complete properly, a
          'SAV ERR' message will be displayed on the next power up.  The message
          can be cleared by pressing either console button.  Please report any
          occurence of this alert message.

    NOTE: This is a special pre-release development version with a temporary
          additional 'Development' Setup Category.  These settings are intended
          for Grin test and development personnel only. The defaults should
          provide workable operation and changes to any setting may cause
          improper device operation with unknown consequences.

    NOTE: This version displays Trip Statistics in Setup Utility.  These
          internal variables are presented for development work and should not
          be altered or improper CA operation may occur.


Should be Working - Please report all issues:

    (01) - all limiting modes (MaxCurrent, MaxPower, etc)
    (02) - all Console Setup screens
    (03) - all Status screens
    (04) - PAS has not been fully vetted but appears working
    (05) - MFS limiting and PAS control (all modes)
    (06) - Custom field displays, MFS-Change pop-ups and Custom Field indicators
    (07) - EE save/restore works on any power-down or SU interaction
    (08) - MFS/AuxA/AuxD functionality
    (09) - Speed/distance displays and calcs working
    (10) - inclinometer functionality implemented as display-only
    (11) - log displays acceleration in new column
    (12) - log displays up to two settings of {MFS,AuxA,AuxD} in cols Ctl[1,2]


Known Issues - Don't report issues if called out below:

    (1) - SOC display does not work
    (2) - GPS functionality unimplemented
    (3) - PAS control by inclinometer unimplemented
    (4) - occational EEPROM corruption on power-up - generally manifest as
          change to custom field selection
    (5) - PAS '1-wire' (non-quadrature) operation may cause issues.
          See task 7523



		
  2020-05-16 [top]