Cycle Analyst 4.0a32 - Release Notes
SETTINGS SUMMARY    CAV4 ONLINE

----- Summary of Changes in this Release -----


Section titles show the feature/problem tracking number and description.


Release: 4.0a32                                                      2020-03-11

    This version is pre-release development firmware packaged exclusively for
    in-house test.  Improper operation may occur.

    This release is a DEMO of new inclinometer UI features. This version is
    intended for a bench operation as there is a heavy processing load that may
    make normal operation unsmooth or jerky (??). Logging is definitely compromised.


    NOTE: This firmware is instrumented to detect illegal writes to any setting
          in EEPROM.  The CA intercepts these errors before they occur, ceases
          normal operation, and displays a special 'watchdog' screen.  If this
          occurs, please record all screen information either by manual
          transcription or (phone) photo, press the right console button, and
          repeat until all screens have been recorded and the CA reboots.

          Please forward the recorded information with a description of the
          failure circumstances to Grin at: info@ebikes.ca.  Please include a
          setup file if possible. Thank you!

    NOTE: This is a special test version with fixed 55Hz data logging of raw
          X/Y/Z acceleration data at the standard 9600 baud rate. Each record is
          comprosed of Xacc, Yacc, Zacc where each value a formatted as a four
          digit hex value with no intervening field separator.
          (e.g. 3155FFCDD5F7 => Xacc=0x3155, Yacc=0xFFCD, Zacc=0xD5F7)

    NOTE: This is a special test version with Setup configuration of
            1) internal LIS2 50Hz filter       ( Misc->50HzFilter )
            2) adjustable digital noise filter ( Misc->NoisFilter )

	  Pitch, roll, and grade calculations use interpolated tables.


Should be Working - Please report all issues:

    (1) - all limitng modes (MaxCurrent, MaxPower, etc)
    (2) - all Console Setup screens
    (3) - all Status screens
    (4) - PAS has not been fully vetted but appears working
    (5) - MFS simple limiting and PAS control (all modes)
    (6) - Custom field displays, MFS-Change pop-ups and Custom Field indicators
    (7) - save/restore of Trip Statistics on power cycle
    (8) - inclinometer status screen and custom view


Known Issues - Don't report issues unless called out below:

    (1) - SOC display does not work
    (2) - Battery/Preset hot swap not vetted
    (3) - AuxA/AuxD functionality has not been vetted
    (4) - Some Speed or Pas glitches may occur
            Please report issues
    (5) - GPS functionality unimplemented
    (6) - inclinometer functionality unimplemented
    (7) - occational EEPROM corruption on power-up - generally manifest as
          change to custom field selection



		
  2020-03-11 [top]